Sensor device – CNB IDC4050F User Manual
Page 9
9 / 17
X
X
N
N
E
E
T
T
N
N
e
e
t
t
w
w
o
o
r
r
k
k
D
D
o
o
m
m
e
e
C
C
a
a
m
m
e
e
r
r
a
a
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
M
M
a
a
n
n
u
u
a
a
l
l
2
2
.
.
3
3
.
.
3
3
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
n
n
g
g
t
t
o
o
A
A
l
l
a
a
r
r
m
m
D
D
e
e
v
v
i
i
c
c
e
e
s
s
Alarm Input
Wires from various sensor type (IR, heat, and magnetic) can be connected to
Alarm
in(+)/(-) terminal as
shown in figure 2.5. (NC or NO of sensor input can be selected at Menu screen.)
Alarm Sensor device requires a separate power source.
Alarm in(+)
Alarm in(-)
Photo Coupler
Sensor
Device
Signal(+5 ~ 30VDC)
GND
Adaptor
+
-
Internal Circuitry External Circuitry
Alarm Output
This terminal can only be connected up to DC 30V/400mA. An additional relay device has to be used to
control higher voltage or current.
ALARM
DEVICE
POWER
Alarm out
Alarm out
+
+
-
-
Internal Circuitry External Circuitry