Local Control Operations
affects how it responds to commands; so it’s important to properly program DIN
Rail for the correct type of switch you are installing. DIN Rail on/off buttons function exactly like the top and bottom of
your wall switch.
Note: LED will blink red for a few seconds if one or more responders do not acknowledge a message.
Latching Wall Switch (Default)
Single Momentary Wall Switch
Dual Momentary Wall Switch
Adjust Local Settings
Local On-Level
Local on-level is the brightness that the load wired into DIN Rail will come on when turned on at the DIN Rail paddle.
The default local on-level is 100% brightness, but it can be set to any one of 32 fixed brightness levels (3% to 100%).
If you want DIN Rail to turn the load on at its last brightness level (prior to being turned off), see
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
Connected load/responders
Latching switch
Tap
LED
Top
On
(ramped)
Green
Bottom
Off
(ramped)
Red
Connected load/responders
Single momentary switch
Tap
Press and hold
Double-tap
LED
Switch
On/Off
(ramped)
Brighten/Dim
(until release or full-
on/off)
On/Off
(instant)
Green/
Red
Connected load/responders
Dual momentary switch
Tap
Press and hold
Double-tap
LED
Top
On
(ramped)
Brighten
(until release or 100%)
On
(instant)
Green
Bottom
Off
(ramped)
Dim
(until release or off)
Off
(instant)
Red