beautypg.com

Phase bridge detect beacon/rf range test, Replacing fuse – INSTEON DIN Rail Dimmer - 2452-222 (US), 2452-422 (EU), 2452-522 (AUS/NZ) Manual User Manual

Page 17

background image

Page 17 of 19

2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM

Phase Bridge Detect Beacon/RF Range Test

Dimmer module automatically bridges the electrical phases in your home (via communications with other dual-band
devices on the “other phase”). This is only important in 2-phase homes with powerline-only INSTEON products or
buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to
see if your devices are within communication range. You will need at least one other INSTEON dual-band device
installed.

1) Press and hold set button until it beeps

LED will start blinking green

2) Press and hold set button until it beeps a second time

LED will start blinking red

3) Press and hold set button until it beeps a third time

LED will start blinking green

4) Slowly tap set button 2 times

LED will continue blinking green

5) Press and hold set button until it beeps

DIN Rail will start beeping once per second
LED will turn solid green

6) Check the LED behavior of other dual-band devices

Phase Bridge Detect Beacon

If the other dual-band device is blinking

green, it is on the other phase:

Device provides a phase bridge to Dimmer module

If the other dual-band device is blinking red, it is on the same phase:

Device does not provide a phase bridge to Dimmer module
Relocate if necessary (and practical)

If the other dual-band device is not blinking:

Device is not within RF range of Dimmer module so it does not provide a phase bridge
Relocate if necessary (and practical) or add an additional dual-band device

RF Range Test

If LED is blinking:

Device is within RF communication range

If LED is not blinking:

Device is not within RF communication range
Relocate if necessary (and practical) or add an additional dual-band device

7) Tap set button

Dimmer module will stop beeping

Other device LEDs will stop blinking

Replacing Fuse

1) Turn off power to device
2) Use a small screwdriver or similar tool to pry up fuse cover
3) Remove fuse cover and fuse
4) Replace fuse with 5x20mm slow blow/burn glass fuse (use 16A for US, 2A for EU and AUS/NZ)
5) Ensure fuse is centered in fuse holder and firmly press fuse and cover into place.
6) Restore power to device
7) Ensure device is functioning properly

If you have tried these solutions, reviewed the owner's manual, and still cannot resolve an issue you are having with
DIN Rail, visit

http://www.insteon.com/support

or call INSTEON Support Line at 866-243-8022.