5 output options, Operation, 2 hold/transfer outputs – Hach-Lange SC 100 User Manual
Page 34: 1 navigating to the output options menu
Output Options
30
Operation
4.5 Output Options
Refer to the
System Setup on page 27
for more information on the output options menu.
The analyzer provides two isolated analog outputs (Output 1 and Output 2).
4.5.2 Hold/Transfer Outputs
During normal measurement operation, the analog outputs can be held at the last measured value
or transferred to a preset value. To hold or transfer the output until released:
4.5.1 Navigating to the Output Options Menu
Step
Select
Menu Level/Instructions
Confirm
1
MAIN MENU
—
2
SYSTEM SETUP
3
OUTPUT SETUP
4
SELECT OUTPUT
5
Customize the options, refer to
System Setup on page 27
.
6
Main Menu or Main Measurement Screen when Output options are configured.
—
Step
Select
Menu Level/Instructions
Confirm
1
MAIN MENU
—
2
TEST/MAINT
3
HOLD OUTPUTS
4
SET OUTMODE
5
Select HOLD OUTPUTS or XFER OUTPUTS
6
SET CHANNELS
7
Select ALL or one of the connected sensors.
—
8
ACTIVATION
9
Select LAUNCH
10
Main Menu or Main Measurement Screen
reading will
flash
- AMTAX sc (118 pages)
- PHOSPHAX sc (106 pages)
- CL17 Instruction sheet (8 pages)
- CL17 USER MANUAL (60 pages)
- CLF10 sc (382 pages)
- 9184 sc (50 pages)
- POLYMETRON 9611 sc Installation (398 pages)
- POLYMETRON 9610 sc Maintenance and Troubleshooting (286 pages)
- POLYMETRON 9611 sc USER INSTRUCTIONS: SEQUENCER LINE INSTALLATION (2 pages)
- POLYMETRON 9611 sc USER INSTRUCTIONS: SS SAMPLE CONDITIONING (4 pages)
- HACH 5500 sc Installation (408 pages)
- HACH 5500 sc Maintenance and Troubleshooting (286 pages)
- HACH 5500 sc PO43-HR Operations (390 pages)
- HACH 5500 sc PO43-LR Operations (392 pages)
- HACH 5500 sc SiO2 Installation (418 pages)
- HACH 5500 sc SiO2 Operations (394 pages)
- POLYMETRON 9610 sc SiO2 Installation (410 pages)
- POLYMETRON 9240 Basic User Manual (162 pages)
- POLYMETRON 9240 Operator Manual (144 pages)
- PHOSPHAX sigma Basic User Manual (305 pages)
- AMTAX inter2 Basic User Manual (377 pages)
- GANIMEDE P (60 pages)
- BODTrak II Basic User Manual (172 pages)
- BODTRACK II User Manual (28 pages)
- BODTRAK II: Respirometric Biochemical Oxygen Demand (BOD) (46 pages)
- SPECTRO COLOR d-8 (29 pages)
- REFO 60_REFO 60D (36 pages)
- REFO 3_REFO 3D (19 pages)
- LICO 620 Basic User Manual (329 pages)
- LICO 620 User Manual (114 pages)
- SD900 (2 pages)
- LZX971 (8 pages)
- SC Sensor Plug and SC Sensor Coupling (8 pages)
- HQ Series Portable Meters (4 pages)
- LDO Sensor Replacement Kit for use with Hach HQ10 and HQ20 (43 pages)
- LDO Sensor Replacement Kit (8 pages)
- SIP 10 (273 pages)
- SI792 E_T Quick start guide (2 pages)
- SI792(x) E HACH GLI 3700 series SI792(x) T 7MA2200 and 8398 series User Manual (116 pages)
- SI792 D Quick start guide (2 pages)
- SI792 D, SI792x D, SI792x D-FF, SI792x D-PA User Manual (98 pages)
- SI794 C and SI794 D Short instructions (2 pages)
- SI794 D tr User Manual (108 pages)
- SI792 C Quick start guide (2 pages)