Clear-Com HME DX200 User Manual
Bp200, Belt-pac, Registration instructions
BP200
Belt-pac
REGISTRATION INSTRUCTIONS
Prior to operation of the DX200 system, each Belt-pac must be registered for use with a specific
base station. The base station will then recognize all registered Belt-pacs when their power is
on, differentiating between them and interfering transmissions from other electronic equipment
operating on similar frequencies. If a Belt-pac is added or replaced later, the new one must be
registered. When a Belt-pac is replaced, the old one remains in memory. A maximum of 15 Belt-
pacs can be registered to a single base station. If the maximum number of 15 (in memory) is
exceeded, an
F will appear in the REGISTRATION STATUS display on the base station and you
will hear “Registration failed” in the headset. If this happens, refer to the last section on the
back of this sheet.
Register each Belt-pac as follows:
NOTE: Belt-pacs must be within 6 feet (1.83 meters) of the base station while being registered.
Be certain all Belt-pacs to be registered are powered off and the base station power is on.
Other Belt-pacs can be on or off.
Press the
REGISTER BELT-PAC button shown in Figure 1.
⎯ After you press the REGISTER BELT-PAC button, the REGISTRATION STATUS display will
show a small “o” for open.
Figure 1. Registration buttons and indicator on left front panel of base station
HM ELECTRONICS, INC.
14110 Stowe Drive, Poway, CA 92064 USA
• Phone: 1-800-848-4468 Fax: (858) 552-0172
HME# 400544
Rev— 3/2/04
NOTE: To press the
RESET button,
insert a small
paper clip or
similar object
into the
RESET
hole.