Specifications – Clear-Com GPI-6 User Manual
Page 13
Vitec Group Communications
GPI-6 Interface Instruction Manual
3 - 1
SPECIFICATIONS
Input
Type
Opto-Isolated current limited
Quantity
6
Voltage Range
5 - 45 volts DC
Input Current
4 - 7 mA
DC Isolation
10 mega-ohms
Module Power Supply Requirements
Voltage Required
8 – 10 volts DC
Current Required
<20 mA
Connectors
Input Connections
2 ea. DB-9M
Matrix Connection
2 ea. RJ-45 ea.
Indicators and Controls
LED Indicators
6 Green (1 each per input)
1 Yellow (Frame Data)
Pushbutton Switches
6 (1 Test Pushbutton per input)
Wiring Requirements
Maximum line lengths for connection to Matrix Frame
Matrix Frame to Interface Frame shall be less than 15 feet (5 meters)
Maximum line length between interface frame inputs 6 inches (15 cm)
Operating Environment
Temperature
0 and 70° C (32 -150° F)
Package Dimensions
Height
5 1/16" (129 mm)
Width
1 3/8" (35 mm)
Depth
9 5/32" (233 mm)
Weight
.35 LBS (.15 kg)
Notice About Specifications
While Vitec Group Communications makes every attempt to maintain
the accuracy of the information contained in its product manuals, that
information is subject to change without notice. Performance
specifications included in this manual are design-center specifications
and are included for customer guidance and to facilitate system
installation. Actual operating performance may vary.
3