Clear-Com HX System Frames User Manual
Page 17
![background image](/manuals/332678/17/background.png)
Key: Eclipse HX-Median front panel
Feature
Description
A
Interface module slots (unused in this example). The Eclipse HX-Median
can house up to 8 interface modules. Blank panels can be installed to unused
slots. For more information about interface modules, see 3.5
B
CPU cards (P1 and P2). 2 CPU cards are supplied with the matrix, but only
one rear-panel CPU card is required. Whichever of the two front-installed CPU
cards is acting as master will work in conjunction with this card. For more
information, see 3.3.1
C
Interface cards. Up to 7 interface cards can be installed to the matrix. Blank
panels can be installed to unused slots. For more information, see 3.4
In Figure 2, the cards shown in slots 1 and 2 are MVX-A16 analog port cards.
MVX-A16 cards are used to connect user panels and interfaces. For more
information about MVX-A16 cards, see 3.3.2
D
Twin power supplies. The two Euro Cassette power supply units can be easily
installed or removed as required. One power supply unit can power an entire
matrix. The second unit provides a backup in case of failure or damage to the
first unit. For more information, see 3.2.2
Table 3: Key to Eclipse HX-Median front panel
17
Eclipse HX-Median User Guide