beautypg.com

Troubleshooting, Troubleshooting -10 – Clear-Com PRC-2 User Manual

Page 16

background image

Vitec Group Communications

PRC-2 UHF Multi-Frequency Belt-Pack IFB Receiver

1 - 1 0

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

LED not lit

• Battery not installed or depleted

• Power switch not on.

No sound in headphone

• AUDIO LEVEL turned all the way

down.

• Headphone plug not inserted fully.

• Defective headphone

• Transmitter not operating. (See

separate transmitter manual.)

• Receiver not on the same frequency

as the transmitter.

• Refer to “Programming - Add a New

Frequency” on page 7.

Distorted sound

• Transmitter gain (audio level) is far

too high. Check mod level lamps
on transmitter as it is being used.
Refer to Operating Instructions
section in the transmitter manual
for details on gain adjustment.)

• Receiver output may be mismatched

with the headset or earphone.
Adjust Audio Level on receiver to
the correct level for the headset or
earphone

• Excessive wind noise or breath

“pops.” Reposition microphone
and/or use a larger windscreen.

• Receiver may be tuned to an

intermod. Reprogram the
receiver.

Hiss and noise

Transmitter gain (audio level) far

too low.