K B - 7 0 2 / K B - 7 0 2 G M T W O - C H A N N E L S P E A K E R

1 - 6

then be accessible as shown in the lower view of Figure 1-3. The numbers in
the left column of the following descriptions refer to Figure 1-3.

Figure 1-3: Internal Adjustments and Connections

13. Call Alert Tone Level Control: This control adjusts the volume of the

call alert tone sound. This is normally adjusted when the system is set up

and there should be no need to adjust it in normal operation. This feature

can be disabled by turning the control fully counterclockwise.

14. Option Switches: Three option switches are provided. They should be

configured when the system is set up, but are not changed in normal

operation. Note the on position of each switch is toward the circuit board

and the off position is toward the front panel. The default position of the

switches is in the off position. The function of each switch is as follows:
1. SINGLE CHANNEL: In some installations, the KB-702 is intended

to be used only with one intercom channel. Setting the single channel

switch to the on position will connect the KB-702 to the one intercom

channel regardless of the position of the front panel channel selector.

In two-channel installations, this switch must be set to the off

position.

2. LONG LINE: If a long cable run is unavoidable and approaches

700 ft. (213.5 m) or more, set the long line option switch to the on

position. The ability to set a sidetone null depends upon properly

setting this switch.

3. LATCH DISABLE: Setting the latch disable switch to the on position

will disable the latching function of the talk button. In this mode, the

talk button must be continuously pressed while the operator is talking.

P1 Call

on Both

P1 Call on

Selected

P3 Must be

installed if

no option

P2 Must be

installed if

no option

1 2 3

15

16

17

14

13

View from top

of KB-702

Front Panel

18