2 - basic cable layout, 3 - low voltage cable layout – CAME Frog-AES24 Kit User Manual
Page 5
1.2 - Basic Cable Layout
THIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FOR
A SINGLE MOTOR.
THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE AND
PROTECTED IN ACCORDANCE WITH THE 16TH EDITION ELECTRICAL
REGULATIONS. THE SUPPLY SHOULD BE RATED AT A MINIMUM OF 6 AMPS.
WHEN INSTALLING WIRES OUTDOORS THE CABLE APPROACH TO ALL
DEVICES MUST BE FROM BELOW TO CREATE A “DRIP-LOOP” AND THEREBY
AVOID UNNECCESSARY WATER INGRESS.
4
1.3 - Low Voltage Cable Layout
WHEN INSTALLING LOW VOLTAGE CABLE AROUND THE GATEWAY IT IS ADVISED TO PUT ALL LOW
VOLTAGE CABLE IN EITHER DUCTING OR ALKATHENE PIPING. ALL CABLE JOINTING SHOULD BE
CARRIED OUT ABOVE GROUND.
ALL CAME ACCESSORIES CAN BE WIRED IN 0.2mm STRANDED LOW VOLTAGE CABLE
(BURGLAR ALARM TYPE). TUNED ANTENNA SHOULD BE WIRED WITH COAXIAL CABLE.
CONTROL
HOUSING
PANEL
JOINT BOX
240V A.C.
3 CORE
SWA 1.5mm
MOTOR CABLE IN DUCTING
Fig 3
TUNED ANTENNA
CONTROL PANEL
HOUSING
COAX CABLE
DOC E SAFETY
BEAMS
8mm CORE 0.2mm
STRANDED TO ALL
SAFETY BEAMS
Fig 4