beautypg.com

7 adjusting the run-limiters, English, 5 adjustments 6.4 function selection – CAME Ver U4512-B Kit User Manual

Page 14

background image

14

ENGLISH

T

h

e d

at

a a

n

d i

n

fo

rm

at

io

n r

ep

o

rt

ed

i

n

t

h

is

i

n

st

al

la

ti

o

n

m

an

u

al

a

re s

u

sc

ep

ti

b

le to c

h

an

g

e a

t a

n

y t

im

e a

n

d w

it

h

o

u

t o

b

li

g

at

io

n o

n

C

AM

E c

an

ce

ll

i a

u

to

m

at

ic

i s

.p

.a

. to n

o

ti

fy

u

se

rs

.

T.C.A. Trimmer =

Adjusts the waiting time in the opening position. Once this time frame has lapsed, an automatic closing

procedure is performed. The waiting time may be adjusted to between 1 second and 120 seconds.

SENS Trimmer =

Adjusts the amperometric sensitivity that controls the force of the engine developed during movement; if said

force becomes greater than the adjusted level, the system intervenes by inverting the direction of movement.

1 ON - Automatic closing – the timer for the automatic closing is activated when the door completes its opening cycle. The set

time is adjustable, and it is any how conditioned by the possible intervention of the safety devices and dies not activate
after a total safety ‘stop’ or during a power outage.

2 ON - ‘open-stop-close-stop’ function with button (2-7) and radio transmitter (with radio frequency card inserted).

2 OFF - ‘open-close-inversion’ function with button (2-7) and radio transmitter (with radio frequency card inserted).

3 ON - ‘open only’ function with radio transmitter (with radio frequency card inserted).

4 ON - Pre-fl ashing upon opening and closing – Following an opening or closing command, the fl ashing light connected on

10-E, fl ashes for 5 seconds before the cycle begins.

5 ON - Detection of obstacle – When motor is not running (gate closed, open or after a total stop command), prevents any

movement if the safety devices (e.g. the photocells) detect an obstacle.

6 ON - “Maintained action” the gate functions by keeping the buttons pressed (one button [2-3] for opening, and one button

[2-7] for closing).

7 OFF - Reclosing during opening cycle – if the photocells detect an obstacle during the gate’s opening cycle, the gate inverts

its direction until it is fully closed; connect the safety device to the terminals (2-C1).

8

Disabled, keep the dip-switch in the ‘OFF’ position

9

Disabled, keep the dip-switch in the ‘OFF’ position

10 ON - Enables the microswitch stop function when gate completely closes.

10 OFF - Enables the slowing-down function of the micro switch when gate is closing.

6.5 Adjustments

6.4 Function selection

7 Adjusting the run-limiters

For the closing cycle, either the stop or the slowing-down functions
can be selected.

Before starting any adjustment operations, position dipswitch 2 to ON
(this dipswitch has 10 positions) and make sure that the safety device
is connected to 2-C1. If there are no safety devices, then position
dipswitch 7 to ON.

IMPORTANT: before performing any programming, read the

instructions carefully.

4#!

3%.3

!0

4#!

3%.3

&53

&53

!##

&53

#(

!02%

!0

!&

ON

OFF

/.

Dip-switch 10

1 OFF - Control unit designed to

work with V700 gearmotors

2

Disabled, keep the dip-
switch in the ‘OFF’ position

Dip-switch 2

ON

OFF

4#!

3%.3

&53

&53

!##

&53

#(

!02%

!0

!&

This manual is related to the following products: