beautypg.com

Alarms – Hydrotech DLR-4M_7M Ultraviolet Water Disinfection Unit User Manual

Page 19

background image

O & M Manual DLR-M, 4-7
08/05 – Rev. 6

19

Alarms,

Continued

What Happens

Cause

How to Resolve

• The UV intensity

HIGH LED blinks.

• The internal

ALARM buzzer
beeps once every 3
minutes.

The UV intensity has dropped
below 70%. Quartz sleeve or
sensor may be dirty.

IMPORTANT!

Water to the

house is being disinfected

.

• Press the RESET button once to

silence the alarm buzzer for 5
days. The alarm buzzer will begin
to beep again 5 days after pressing
the RESET button and continue
until the problem is resolved and
the unit reset.

• Perform routine maintenance as

indicated in the manual.

• Clean quartz sleeve and UV sensor

quartz.

• If the problem persists, have local

water treatment dealer check the
water quality.

• The UV intensity

HIGH LED is no
longer illuminated.

• The UV intensity

LOW LED blinks.

• The internal

ALARM buzzer
beeps continuously.


The UV intensity has dropped
below 50% indicating that there
may be a potential problem within
the UV disinfection unit. Quartz
sleeve or sensor may be dirty.

WARNING

!

Disinfection

may be insufficient to ensure
safe drinking water. Do not
drink water without boiling or
disinfecting through some
other means

.

• Press the RESET button once to

silence the alarm buzzer for 5
days. The alarm buzzer will begin
to beep again 5 days after pressing
the RESET button and continue
until the problem is resolved and
the unit reset.

• Perform routine maintenance as

indicated in the manual.

• Clean quartz sleeve and UV sensor

quartz.

• If the problem persists, have local

water treatment dealer check the
water quality.

• The UV intensity

HIGH LED is no
longer illuminated.

• The UV intensity

LOW LED blinks.

• The REPLACE

LAMP LED is
illuminated

• The ALARM LED

blinks.

• The internal

ALARM buzzer
beeps continuously.

• If the unit has an

optional solenoid
valve, it will shut off
water supply.

The UV intensity has dropped to
zero.





WARNING!

UV system is not

operational. Do not drink
water without boiling or
disinfecting through some
other means.

• Press the RESET button once to

silence the alarm buzzer for 5
days. The alarm buzzer will begin
to beep again 5 days after pressing
the RESET button and continue
until the lamp is replaced and the
unit reset.

• Perform routine maintenance as

indicated in the manual.

• Clean quartz sleeve and UV sensor

quartz.

• Replace lamp and quartz sleeve, if

necessary.

• If the problem persists, have local

water treatment dealer check the
water quality.