08/05 – Rev. 6

18

Alarms


Displays

The front panel of the electrical control box has the following LED displays:

LED Displays

Diagram


LED Displays:

• LAMP ON: green

• REPLACE LAMP: red
• ALARM: red
• UV intensity HIGH: green
• UV intensity LOW: yellow










Alarm
activation




The WEDECO UV disinfection unit has built in alarms to warn of inefficient
performance or lamp failure.

What Happens

Cause

How to Resolve

• The REPLACE

LAMP LED blinks.

• The internal ALARM

beeps once every 5
minutes.

The internal counter has reached 30
days of lamp life remaining.

IMPORTANT!

Water to the

house is being disinfected and
the solenoid valve (optional)
will remain open.

• Press the RESET button once to

silence the alarm buzzer for 5
days. The alarm buzzer will begin
to beep again 5 days after pressing
the RESET button and continue
until lamp has been replaced and
the unit reset.

• Replace UV lamp within 30 days

to ensure optimum performance
from the unit.

• The LAMP ON LED

is no longer
illuminated.

• The REPLACE

LAMP LED is
illuminated
continuously.

• The ALARM LED

blinks

• The internal ALARM

buzzer beeps
continuously.

The internal counter has reached 0
(zero) days of lamp life. Or, lamp
has failed due to another problem.
(See Troubleshooting section.)



WARNING!

Disinfection may

be insufficient to ensure safe
drinking water. Do not drink
water without boiling or
disinfecting through some
other means.

• Press the RESET button once to

silence the alarm buzzer for 5
days. The alarm buzzer will begin
to beep again 5 days after pressing
the RESET button and continue
until lamp has been replaced and
the unit reset.

• Replace lamp immediately. Follow

instructions on lamp replacement
in the manual.