Model 5600 sxt-diagnostics chart – Hydrotech 5600 SXT User Programming Chart User Manual

Page 9

background image

Display is D (DAY OF WEEK)

→used to set the day of week in which the regeneration should

occur [Factory Setting: OFF]. Press UP/DOWN buttons to adjust the setting. ONLY
AVAILABLE IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.





Display is CD (CURRENT DAY)

used to set the current day of week in which the

regeneration should occur Press UP/DOWN buttons to adjust the setting. ONLY AVAILABLE
IF CONTROL TYPE IS SET TO DAY OF WEEK SETTING.





Display is FM (FLOW METER TYPE)

→ [Factory Setting: t0.7].Do not change this setting.





RETURN TO SERVICE

Model 5600 SXT-Diagnostics Chart

To enter the diagnostic mode, push and hold and button for 5 seconds.

Display is FR (CURRENT FLOW RATE)

→ display current flow rate in gallons per minutes.




Display is PF (PEAK FLOW RATE)

→ display peak flow rate in gallons per unit since the last

regeneration cycle.




Display is HR (HOURS IN SERVICE)

→ display to view the hours in service since the last

regeneration cycle.





Display is VU (VOLUME USED)

→display the volume in gallons used since the last

regeneration cycle.


Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

UP

UP

Extra Cycle

Button

UP

UP

UP