Model 5600 SXT- Master Programming Chart


FROM SERVICE MODE:-


To enter master programming mode, set the Time of Day display to 12:01 P.M.



Press and hold

and buttons together until the programming icon


replaces the service icon

Display is DF (DISPLAY FORMAT)

→ Unit of measure for volume and display format for

time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings.


Display is VT (VALVE TYPE)

type of valve setting [Factory Setting: Fltr (Filter)]. Press

UP/DOWN buttons to adjust the settings.

Display is CT (Control Type)

type of regeneration [Factory Setting: Fd (Meter Delayed)].

Press UP/DOWN buttons to adjust the settings.



Display is NT (Number of Tanks)

[Factory Default Setting: 1]. Do not change the setting.






Display is UNIT CAPACITY

Capacity in gallons. [Factory Default Setting: 10000 gallons]

].

Press UP/DOWN buttons to adjust the value.


Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

UP

DOWN