Press UP/DOWN buttons to adjust the value.
↓
↓
↓
↓
↓
↓
↓
↓
Display is H (WATER HARDNESS) →
→
→
→ Grains per Gallon for softener and ppm per gallon of
iron for iron filters will appear [factory default setting grains per gallons for Softeners – 15gpg
Iron content in ppm per gallon for Iron Filters – 20ppm].
Press UP/DOWN buttons to adjust the value.
↓
↓
↓
↓
↓
↓
↓
↓
Display is RS (RESERVE SELECTION) →
→
→
→ Type of reserve [Factory Default Setting: RC
(Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting.
↓
↓
↓
↓
↓
↓
↓
↓
Display is RC (FIXED RESERVE CAPACITY) →
→
→
→ Reserve capacity in gallons [Factory
Default Setting: 0]. Press UP/DOWN buttons to adjust the value.
↓
↓
↓
↓
↓
↓
↓
↓
Display is DO (DAY OVERRIDE) →
→
→
→ [factory default setting: OFF]. Press UP/DOWN buttons
to adjust the setting.
↓
↓
↓
↓
↓
↓
↓
↓
Display is RT (REGENRATION TIME) ([default: For Iron Filters – 11:00 P.M.
For Softeners – 2:00 A.M.]
Press UP/DOWN buttons to adjust the time.
↓
↓
↓
↓
↓
↓
↓
↓
Display is BW (BACKWASH)→
→
→
→ [Factory Setting: For Iron Filter and Softener10 (10 minutes)
For Chemical Free Iron Filters 6 (6 minutes)
]. Press UP/DOWN buttons to adjust the time.
↓
↓
↓
↓