Press UP/DOWN buttons to adjust the value.



Display is H (WATER HARDNESS)

Grains per Gallon for softener and ppm per gallon of

iron for iron filters will appear [factory default setting grains per gallons for Softeners – 15gpg

Iron content in ppm per gallon for Iron Filters – 20ppm].

Press UP/DOWN buttons to adjust the value.


Display is RS (RESERVE SELECTION)

→ Type of reserve [Factory Default Setting: RC

(Fixed Reserve Capacity)]. Press UP/DOWN buttons to adjust the setting.




Display is RC (FIXED RESERVE CAPACITY)

Reserve capacity in gallons [Factory

Default Setting: 0]. Press UP/DOWN buttons to adjust the value.





Display is DO (DAY OVERRIDE)

[factory default setting: OFF]. Press UP/DOWN buttons

to adjust the setting.




Display is RT (REGENRATION TIME) ([default: For Iron Filters – 11:00 P.M.

For Softeners – 2:00 A.M.]

Press UP/DOWN buttons to adjust the time.




Display is BW (BACKWASH)

→ [Factory Setting: For Iron Filter and Softener10 (10 minutes)

For Chemical Free Iron Filters 6 (6 minutes)


]. Press UP/DOWN buttons to adjust the time.