Display is CD (CURRENT DAY OF THE WEEK). Press UP/DOWN buttons to adjust the
current day of the week. ONLY AVAILABLE IF DAY OF THE WEEK CONTROL IS
ON IN MASTER PROGRAAMING

Model 5600 SXT- Master Programming Chart


FROM SERVICE MODE:-


To enter master programming mode, set the Time of Day display to 12:01 P.M.



Press and hold

and buttons together until the programming icon


replaces the service icon

Display is DF (DISPLAY FORMAT)

→ Unit of measure for volume and display format for

time [Factory Default Setting: GAL]. Press UP/DOWN buttons to adjust the settings.


Display is VT (VALVE TYPE)

type of valve setting [Factory Setting: St1b (Standard

Downflow/Upflow, Single Backwash]. Press UP/DOWN buttons to adjust the settings.

Display is CT (Control Type)

type of regeneration [Factory Setting: Fd (Meter Delayed)].

Press UP/DOWN buttons to adjust the settings.



Display is NT (Number of Tanks)

[Factory Default Setting: 1]. Do not change the setting.






Display is UNIT CAPACITY

Capacity in grains for softeners and in ppm per gallon for iron

filters.

[Factory Default Setting: Refer to User

Manual].

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

Extra Cycle

Button

UP

DOWN