Diagnostic Programming Mode
Diagnostic Programming Mode Options
Abbreviation
Parameter
Description
FR
Flow Rate
Displays the current outlet fl ow rate
PF
Peak Flow Rate
Displays the highest fl ow rate measured since the last regeneration
HR
Hours in Service
Displays the total hours that the unit has been in service
VU
Volume Used
Displays the total volume of water treated by the unit
RC
Reserve Capacity
Displays the system’s reserve capacity calculated from the system
capacity, feedwater hardness, and safety factor
SV
Software Version
Displays the software version installed on the controller
NOTES:
Some items may not be shown depending on timer confi guration.
The timer will exit Diagnostic Mode after 60 seconds if no buttons are pressed.
Press the Extra Cycle button to exit Diagnostic Mode at any time.
Diagnostic Programming Mode Steps
Press the Up and Extra Cycle buttons for fi ve seconds while in service.
1.
Use this display to view the current Flow Rate. This option setting is identifi ed by “FR” in the upper left hand
2.
corner of the screen.
Press the Up button. Use this display to view the Peak Flow Rate since the last regeneration cycle. This
3.
option setting is identifi ed by “PF” in the upper left hand corner of the screen.
Press the Up button. Use this display to view the Hours in Service since the last regeneration cycle. This
4.
option setting is identifi ed by “HR” in the upper left hand corner of the screen.
Press the Up button. Use this display to view the Volume Used since the last regeneration cycle. This option
5.
setting is identifi ed by “VU” in the upper left hand corner of the screen.