Master programming mode – Hydrotech ProFlo SXT Upflow Automatic Water Softeners Service Manual User Manual
Page 14

Page 14
Master Programming Mode
CAUTION: Before entering Master Programming, please contact your local professional water dealer.
5. Tank in Service (Display Code TS)
Press the Extra Cycle button. Use this display to set whether tank one or tank two is in service. This option setting
is identifi ed by “TS” in the upper left hand corner of the screen. This parameter is only available if the number of
tanks has been set to 2. There are two possible settings:
Tank One in Service:
U1
Tank Two in Service:
U2
6. Unit Capacity (Display Code C)
Press the Extra Cycle button. Use this display to set the Unit Capacity. This setting specifi es the treatment
capacity of the system media. Enter the capacity of the media bed in grains of hardness when confi guring a
softener system, and in the desired volume capacity when confi guring a fi lter system. This option setting is
identifi ed by “C” in the upper left hand corner of the screen. The Unit Capacity parameter is only available if the
control type has been set to one of the metered options. Use the Up and Down buttons to adjust the value as
needed.
7. Feedwater Hardness (Display Code H)
Press the Extra Cycle button. Use this display to set the Feedwater Hardness. Enter the feedwater hardness in
grains per unit volume for softener systems, or 1 for fi lter systems. This option setting is identifi ed by “H” in the
upper left hand corner of the screen. The feedwater hardness parameter is only available if the control type has
been set to one of the metered options. Use the Up and Down buttons to adjust the value as needed.
Range: 1-999,9900 grain capacity
Range: 4-199 hardness