Section 5: Plumbing System Clean-Up

The following procedures are guidelines only but have proven successful in most instances. Under no circumstances

should any procedure outlined below be followed if contrary to the appliance manufacturer’s instructions. Should there

be any questions concerning the advisability of performing a procedure, it is strongly recommended the manufacturer’s

authorized service outlet be consulted prior to performing the procedure.
The plumbing system and water using appliances that have been exposed, even for a short time, to iron-fouled water

need to be cleaned of the precipitated iron that has collected in them or iron bleed (staining) will continue to be a

problem.
Depending on the amount of iron in the water and the length of time the water system has been exposed to iron fouling,

select from the following procedures those that apply to the type of system and appliances that need to be cleaned to

assure iron-free water at the point of use.

Softener

It isn’t uncommon that a softener was installed in an effort to remove ferrous (“clear water”) iron from the water supply.

Typically, a softener will remove some ferrous iron until the resin bed becomes fouled to the extent that it will lose both

hardness removal capacity and the limited capacity for iron removal. This is the condition to expect a softener to be in

when planning a system clean-up.
Prior to closing the main supply valve or turning power off to private well system and preparatory to installing the filter

system, do the following:
1. Disconnect brine draw line from the brine cabinet and place the loose end into a five gallon plastic pail filled with a

solution of warm water and 4 oz. of resin mineral cleaner.

2. Manually advance control timer to brine draw position (refer to instructions provided with your softener). Allow all the

warm mineral cleaner solution to be drawn into mineral bed.Then immediately:

3. Close main water supply valve or turn power off to pump and proceed with filter installation. During time required to

install filter system, iron-fouled softener resin will be chemically cleaned.

4. After filter installation is completed and final adjustments are made with the water turned on and brine draw tube

reconnected, manually reposition timer on softener to backwash position. Allow timer to perform an automatic

regeneration cycle. During backwash of softener, all iron cleaned from the resin will be washed down the drain. It

is advisable, after chemically cleaning softener, to regenerate system twice to fully restore capacity lost due to iron

fouling.

Water Heater

If the water heater has been exposed to both iron and hardness for a long period of time, replacement of the heater tank

may be the only solution to prevent continued staining originating from this source.
After completing the installation of the chemical free iron filter system, clean the water heater by following these

instructions:
1. Shut off energy supply to water heater and close heater inlet water valve.
2. Drain hot water tank completely. Open inlet water valve allowing heater tank to be refilled with iron-free water.

Continue flushing until water runs clear to drain.

3. If, after approximately 30 minutes flushing, water does NOT clear, terminate flushing operation. Refill hot water heater

with water and pour approximately 1/2 gallon of household bleach into top of heater tank. Allow bleach solution to

stand in tank for 20 to 30 minutes. Flush tank again until water is clear at drain. Turn energy supply on.

NOTE: If water does not clear in approximately 10 minutes, water heater should probably be replaced.

Dishwasher

Consult owner’s handbook and follow manufacturer’s instructions.

Toilet Flush Tanks

Prior to commencing installation of the filter system, pour 4 to 6 ounces of resin mineral cleaner Pro-Rust Out or

inhibited muriatic acid into flush tanks and bowls and let stand. When installation is completed, flush toilets several times

with iron-free water. If iron deposits or stains remain, repeat procedure until clear.