8

NOTES:

Some items may not be shown depending on timer configuration.

The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds.

User Programming Mode Steps

1. Press the Up and Down buttons for five seconds while in

service, and the time of day is NOT set to 12:01 PM.

2. Use this display to adjust the Day Override. This option

setting is identified by “DO” in the upper left hand corner

of the screen.

THIS IS AN OPTION ONLY. PLEASE DO NOT ADjUST

BEFORE CONSULTING AN AUTHORIzED DEALER.

User Programming Mode Options

Abbreviation

Parameter

Description

DO

Day Override

The timer’s day override setting

THIS IS AN OPTION ONLY. PLEASE DO NOT ADjUST

BEFORE CONSULTING AN AUTHORIzED DEALER.

RT

Regeneration Time

The time of day that the system will regenerate (meter delayed,

timeclock, and day-of-week systems)

H

Feed Water Iron Content

The iron content in ppm of the inlet water - used to calculate

system capacity for metered systems

RC

Reserve Capacity

The fixed reserve capacity

CD

Current Day

The current day of week

Set Time of Day

1. Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the

parameter display reads TD.

2. Adjust the displayed time with the Up and Down buttons.

3. When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also return to

normal operation after 5 seconds if no buttons are pressed.

Queueing a Regeneration

1. Press the Extra Cycle button. The service icon will flash to indicate that a regeneration is queued.

2. To cancel a queued regeneration, press the Extra Cycle button.

Regenerating Immediately

Press and hold the Extra Cycle button for five seconds.

Installation Tip: The 2510AIO SXT Filter should not be allowed to regenerate at the same time as any other water

treatment units. If adjustment is required, consult programming chart to adjust default regeneration time. Default setting

is 11:00 pm.)