12. Starting with bundles 4-7, 5-8, 6-9, gently
tuck these 3 wire bundles behind the
windings on one side of stator. Then slide
insulation wrap back over wires then tuck
the remaining 3 bundles behind the
windings on the other side. Take care that
all wires are tucked in between stator
winding and housing. Also check that
white phase paper is in proper position,
and not extending above the stator
housing.
The pump is now ready for reassembly
13. Verify that the large o ring is still in its
proper position on the pump housing.
Gently place motor cap back onto pump.
14. With motor cap back in position, then
align bolt holes and replace capscrews.
Tighten capscrews to 12 ft/lbs.
15. Pump should now be ready for installation
and operation at 460V. Be sure to record
that voltage has been changed in pump
service manual.