CITIZEN iDP-3410 User Manual
Page 34
iDP-3410 User’s Manual
9.3
Input and Output Signals
9.3.1 Input and Output Signals
(1) Input signals to the printer
•
DATA
: An 8-bit parallel signal. (Positive logic)
•
STB
: A strobe signal to read the 8-bit data. (Negative logic)
•
RESET
: A signal to reset the printer from the outside.(Negative logic)
(2) Output signals from the printer
•
ACK
: An 8-bit data request signal. A pulse signal output at the end of the BUSY signal.
(Negative logic)
•
BUSY
: A signal to indicate the BUSY status of the printer. Input new data when at "LOW".
(Positive logic)
•
FAULT
: A signal turned to "LOW" when the printer has an alarm. At this time, all the control
circuits in the printer stop. (Negative logic)
•
SELECT
: A signal to show whether the printer is selected(on-line) or deselected.(Positive
logic)
•
COMPULSION
: A signal to show the status of the drawer switch.(Positive logic)
•
PE:
A signal to show that the paper has run out. Normal at the "LOW" level, but turned to
the "HIGH" level when the paper has run out.
(3) Power related signal
•
GND
: Common ground on the circuits
•
Vcc
: A +5V signal. Connected via a 3.3k
Ω