Esc "p" m n1 n2 – CITIZEN iDP-3410 User Manual
Page 108
iDP-3410 User’s Manual
ESC "p" m n1 n2
[Function]
Specifying the pulse generation
[Code]
<1B>H <70>H m n1 n2
[Range]
0
≤
m
≤
1
0
≤
n1
≤
n2
≤
255
[Outline]
This command outputs the signals specified with n1 and n2 to the connector pins.
m
Connector Pin
0
Drawer kick connector No. 2 pin
1
Drawer kick connector No. 5 pin
The ON time is n1
×
2 mS and the OFF time is n2
×
2 mS.
[Caution]
The user should consider driving the drawer at the following duty ratio.
ON time
÷
(ON time + OFF time)
≤
0.2
(It is recommended to make n2 four times higher or more than n1.)
The drawer kick-out solenoid should have a resistance value of 36
Ω
or more. Do not use a
lower one because an overcurrent will flow. For the drawer power, be sure to use the printer
power (Drawer kick-out connector No. 4 pin).