beautypg.com

Electrical data, Electrical connection, Installation and commissioning safety instructions – Burkert Type 8030 User Manual

Page 5

background image

16

Table 1: Dimension H [mm] of the 8030 HT depending

on the DN of sensor-fitting S030 HT

dn

h with sensor-

fitting s030 ht

H

06

95,5

08

95,5

15

100,5

20

98

25

98

32

102

40

105,5

50

112

32

40

66

44

54

9

Fig. 1: Dimensions [mm] of electronic module SE30 HT

English

17

materials

Part

Material

Housing

PPS, glass fibre reinforced

Male fixed connector

PA

Female connector

type 2508 / screw /

seal

PA / Stainless steel / NBR

Sensor-fitting

S030 HT

refer to the operating instructions of the

fitting used.

electrical data

Version with pulse outputs
Supply voltage

12-36 V DC, filtered and
regulated

Current consumption

10 mA max.

Protection against polarity
reversal

yes

Protection against spike
voltages

yes

Protection against short
circuits

yes

English

17

18

Version with pulse outputs
NPN and PNP, open collector, 700 mA max., frequency
up to 250 Hz, duty cycle 1/2 ±10%
NPN output: 0,2-30 V DC
PNP output: supply voltage

Version with sinus output:
Supply voltage

without

Frequency up to 500 Hz, about 2,8 mV peak-to-peak/Hz
under a 50 kΩ load

electrical connection

type of connector

cable type

Female connector type
2508 (supplied), order
code 438811

• shielded, max. 50 m
• 5 to 8 mm in diameter
• wires between 0,25 and

1,5 mm

2

in cross section

English

19

7. insTAllATion AnD

commissioninG

safety instructions

danger

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure

and drain the pipe before loosening the process

connections.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before

loosening the process connections.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident pre-

vention and safety relating to the use of hazardous

products.

English

19