16
Table 1: Dimension H [mm] of the 8030 HT depending
on the DN of sensor-fitting S030 HT
dn
h with sensor-
fitting s030 ht
H
06
95,5
08
95,5
15
100,5
20
98
25
98
32
102
40
105,5
50
112
32
40
66
44
54
9
Fig. 1: Dimensions [mm] of electronic module SE30 HT
English
17
materials
Part
Material
Housing
PPS, glass fibre reinforced
Male fixed connector
PA
Female connector
type 2508 / screw /
seal
PA / Stainless steel / NBR
Sensor-fitting
S030 HT
refer to the operating instructions of the
fitting used.
electrical data
Version with pulse outputs
Supply voltage
12-36 V DC, filtered and
regulated
Current consumption
10 mA max.
Protection against polarity
reversal
yes
Protection against spike
voltages
yes
Protection against short
circuits
yes
English
17
18
Version with pulse outputs
NPN and PNP, open collector, 700 mA max., frequency
up to 250 Hz, duty cycle 1/2 ±10%
NPN output: 0,2-30 V DC
PNP output: supply voltage
Version with sinus output:
Supply voltage
without
Frequency up to 500 Hz, about 2,8 mV peak-to-peak/Hz
under a 50 kΩ load
electrical connection
type of connector
cable type
Female connector type
2508 (supplied), order
code 438811
• shielded, max. 50 m
• 5 to 8 mm in diameter
• wires between 0,25 and
1,5 mm
2
in cross section
English
19
7. insTAllATion AnD
commissioninG
safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure
and drain the pipe before loosening the process
connections.
risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before
loosening the process connections.
risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident pre-
vention and safety relating to the use of hazardous
products.
English