beautypg.com

Burkert Type 8030 User Manual

Page 4

background image

12

Available versions of electronic
module se30 HT

All the electronic modules have to be connected via a male
fixed connector and are fitted with a flow sensor with coil.

supply voltage

output

order code

12-36 V DC

2 pulse outputs,
NPN and PNP

449694

without

1 sinus output

449693

Order codes of the sensor-fitting S030 HT can be found
within the data sheet of type 8030 HT: refer to the data
sheet to select the fitting appropriate to the process.

English

13

6. TecHnicAl DATA
conditions of use

Ambient temperature
(operating)

• Version with pulse outputs:
-15 to +80 °C

• Version with sinus output:
-15 to +100 °C

Air humidity

< 80%, non condensated

Protection rating

IP65 acc. to EN 60529, female
connector wired, plugged and
tightened

conformity to standards and
directives

The device conforms to the EC directives through the
following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: The sensor-fitting S030 HT complies with

article 3 of §3 from 97/23/CE pressure directive.

English

13

14

Acc. to pressure directive 97/23/CE, the fitting can only
be used in the following cases (depending on the max.
pressure, the DN of the pipe and the fluid):

type of fluid

conditions

Fluid group 1 § 1.3.a only DN ≤ 25
Fluid group 2 § 1.3.a DN ≤ 32

or DN > 32 and PNxDN ≤ 1000

Fluid group 1 § 1.3.b PNxDN ≤ 2000
Fluid group 2 § 1.3.b DN ≤ 200

General data

Pipe diameter

DN6 to DN50. The appropriate dia-
meter is determined using the flow
rate / DN / fluid velocity graphs. See
Table 2

Pressure class

Depends on the fluid temperature:
refer to the operating instructions of
the fitting used.

Fitting

S030 HT: refer to the related operating
instructions

English

15

Fluid temperature

• -15 to +125 °C
The fluid temperature may be restricted
by the fluid pressure: refer to the ope-
rating instructions of the sensor-fitting
S030 HT.

Type and data of the
fluid

refer to the operating instructions of
the fitting used.

Flow rate measuring

range

0,5 to 10 m/s

Accuracy, with standard

K factor

≤ ±

(1 % of the full scale + 3 % of the

measured value)*

Linearity

≤ ± 0,5 % of the full scale

Repeatability

± 0,4 % of the measured value*

* Determined in the following reference conditions: medium =
water, water and ambient temperatures 20 °C, min. upstream and
downstream distances respected, appropriate pipe dimensions

English

15