SPECIFICATIONS
Step Two
Service:
Compatible liquids
Wetted Materials:
Sensor:
316 SS
Cable:
Polyurethane or ETFE
Seals:
Fluoroelastomer
Diaphragm: PTFE coated FKM fluoroelastomer (LD35 series only)
Label:
Polyethylene polyamide
Accuracy:
±0.25% of full scale
Temperature Limit:
‐4 to 176°F (‐20 to 80°C)
Compensated
Temperature Limits:
LD34 series: 0 to 158°F (‐18 to 70°C)
LD35 series: 32 to 140°F (0 to 60°C)
Thermal Effect:
LD34 series: ±0.45% FS TEB
LD35 series: ±0.0075%/°F (±0.0135%/°C)
Pressure Limit:
2X full scale
Power Requirement:
10 to 33 VDC
Output Signal:
4 to 20 mA DC, 2‐wire
Response Time:
< 50 ms
Max. Loop Resistance:
1000 ohms @ 30 VDC
Electrical Connections:
Wire pigtail
Cable Length:
‐__01/‐__11: 40’ (12.2 m)
‐__21/‐__31: 60’ (18.3 m)
Mounting Connection:
Suspended below point being monitored
Electrical Protection:
Surge/lightning protected per EN61000‐4‐5, Class 5
Sensor Weight:
LD34 Series: Sensor: 0.235 lb (0.107 kg)
LD35 Series: Sensor: 0.3 lb (0.136 kg)
All:
Cable: 0.037lb (0.009 kg) per foot
Classification:
General Purpose
Compliance:
CE