INSTALLATION

The installation procedures have two sections for each type of interface.

1. Parallel Port interface

2. PC Card (PCMCIA) interface

The procedure includes hardware and software installation. Just follow along
the interface of your choice.

INSTALLATION FOR PARALLEL PORT INTERFACE

HARDWARE INSTALLATION

Before you begin, make sure you turn OFF all power to your system before
connecting the CD ReWriter to your computer.

1. Connect the DC Input adapter cable to the EXP CD drive assembly.
2. Connect one end

of the Parallel
cable to EXP CD
(26 pin small
connector), and
connect the other
end to computer
parallel port.
(standard 25
connector)

3. Plug-in the AC adapter to a working AC receptacle.

4. Press power button.

You are now ready to install the software.

CAUTION

SOFTWARE INSTALLATION FOR WINDOWS 95/98

Check all the connection as states in the “Hardware Installation” section.

From the Desktop Click ‘My Computer’ icon, ‘Control Panel’ and then ‘Add
New Hardware’

1. Click "Next>" to begin.

2. When prompted whether to search for your new hardware,

Select "No" and click "Next>".

The CD and electronic components installed on the CD ReWriter are very
sensitive to damage from static electricity. Before handling the unit, touch a
grounded metal surface. DO NOT connect/disconnect the CD ReWriter

unit

to/from the parallel cable when the system is in power-on state.