Restoring the Lock to Factory Default Setting

• Remove power (disconnect 9V battery) from Lock
• Press and Hold EMTEK button
• While continuing to hold EMTEK button, restore power (reconnect 9V battery)
• Continue to hold EMTEK button for 3 seconds
• 1 Green LED Flash and 2 short beeps followed by 1 Green LED Flash and 2 short
beeps indicates the lock has been successfully restored

This procedure clears the lock of all users and restores the Programming Code and

2 User Codes shipped with the lock.

Function

Indicators

Valid Code

• 1 short beep, EMTEK button flashes

Green.

Invalid Code/Access Denied*

• 1 Red LED flash

• 2 short beeps

Lock-Out Mode Error

• 2 short beeps

• 1 short beep per second for duration

Access Accepted

• 1 short beep

• 1 Green LED flash

Low Battery

• 4 Red LED flashes

• 4 short beeps

Blackout Battery

**

• 1 long Red LED flash

• 4 long beeps

Button Press Accepted

• 1 Yellow LED flash

• 1 Short Beep

Outside Thumb Turn Enabled

• 2 Green LED flashes

* If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a flashing Red EMTEK

button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is

entered the lock will beep quickly 10 times to alert of the incorrect codes.

** Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.