Solution general specifications, Model features, Guide – eLine Technology AN2 Series User Manual
Page 2

CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning with an arrowhead symbol, within an equilateral triangle
is intended to alert the users to the presence of un-insulated
“dangerous voltage” within the product’s enclosure that may be
sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point with an equilateral triangle is intended to alert
the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the appliance.
This equipment has been tested and found to comply with limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.
Changes or modifications not expressly approved by the manufacturer
could void the user’s authority to operate the equipment.
To prevent electric shock and risk of fire hazards:
• Do NOT use power sources other than that specified.
• Do NOT expose this appliance to rain or moisture.
This installation should be made by a qualified service
person and should conform to all local codes.
1
2
Guide
Solution General Specifications
General
Power source
Regulated 12VDC
Power Consumption
100mA IR LED
IR LED On Power
10pcs Max 275mA
15pcs Max 320mA
Scanning system
Progressive Scan Sensor
Scanning frequency
NTSC 15.734KHz( H), 59.95Hz (V) / PAL 15.625KHz (H), 50Hz (V)
Effective Pixels
1305(h) x 1049(V)
Resolution
900TVL
OSD Control
Optional Control via cable (see OSD Menu Page 7-8)
ACG / BLC
On
Noise Reduction
2d/ 3d Enabled
Sync System
Internal
Min. Illumination
0.01 Lux (AGC On, IE Off) / 0 Lux with IR LED On
Video output
1.0 Vp-p (75Ω , composite)
S/N Ratio
More than 52dB (AGC OFF)
Video output
BNC Connector 1.0Vp-p PAL / NTSC
Lens mount
Fixed mount
Lens
Matching for each model.
Operating temperature
-10°C ~ +50°C / -40°F ~ 122°F
Operating humidity
0-90% (non-condensing)
Model Features:
• 1/3” CMOS Sensor
• 900TVL Sensor imaging
• Day/Night / ICR
• Programming via OSD
• BNC Video Output
• Standard 12VDC Operation lower power
• Super flux IR LED for night vision
• 3D Noise reduction
*Specifications subjected to change without prior notice.