Code Faults

Cause
of the
fault

Description

Checking / solution

L00

PSU FAIL

PCU

The PSU integrated in the SU is

defective

Parameters faulty

4

Contact the professional who takes care of

maintenance of the appliance

L01

PSU PARAM FAIL

PCU

The safety parameters are incorrect Parameters faulty

4

Contact the professional who takes care of

maintenance of the appliance

L02

STB OUTLET

SU

Boiler temperature too high

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

No water circulation

4

Vent the air in the heating system

4

Check the circulation (direction, pump,

valves)

4

Check the water pressure

L03

DEF.OIL.SENSOR

SU

The oil pressure measurement

sensor is faulty

Bad connection

The oil pressure measurement sensor is faulty

4

Contact the professional who takes care of

maintenance of the appliance

L04

BURNER FAILURE

SU

Burner start-up failure

No ignition

4

Contact the professional who takes care of

maintenance of the appliance

No flame signal.

Air present in the oil circuit.

4

Check that the oil valve is actually open

4

Contact the professional who takes care of

maintenance of the appliance

Presence of the flame but insufficient ionization

(<3 µA)

4

Check that the oil valve is actually open

4

Contact the professional who takes care of

maintenance of the appliance

L05

DEF.INTERNAL

SU

Internal SU fault

The safety control box on the burner is defective

4

Contact the professional who takes care of

maintenance of the appliance

L06

DEF.SPEED.MOT

SU

Fault on the burner motor

The safety control box on the burner is defective

4

Contact the professional who takes care of

maintenance of the appliance

The burner motor is defective

4

Contact the professional who takes care of

maintenance of the appliance

L07

DEF.T.WARM UP

SU

Preheating period exceeded

The reheat fuel oil is defective

4

Contact the professional who takes care of

maintenance of the appliance

The safety control box on the burner is defective

4

Contact the professional who takes care of

maintenance of the appliance

L08

PARASIT FLAME

SU

Detection of a parasite flame

Signal present whilst there is no flame

4

Contact the professional who takes care of

maintenance of the appliance

L09

OIL.PRES FAIL.

SU

Oil pressure over limit

4

Contact the professional who takes care of

maintenance of the appliance