Code Faults
Cause
of the
fault
Description
Checking / solution
L00
PSU FAIL
PCU
The PSU integrated in the SU is
defective
Parameters faulty
4
Contact the professional who takes care of
maintenance of the appliance
L01
PSU PARAM FAIL
PCU
The safety parameters are incorrect Parameters faulty
4
Contact the professional who takes care of
maintenance of the appliance
L02
STB OUTLET
SU
Boiler temperature too high
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
No water circulation
4
Vent the air in the heating system
4
Check the circulation (direction, pump,
valves)
4
Check the water pressure
L03
DEF.OIL.SENSOR
SU
The oil pressure measurement
sensor is faulty
Bad connection
The oil pressure measurement sensor is faulty
4
Contact the professional who takes care of
maintenance of the appliance
L04
BURNER FAILURE
SU
Burner start-up failure
No ignition
4
Contact the professional who takes care of
maintenance of the appliance
No flame signal.
Air present in the oil circuit.
4
Check that the oil valve is actually open
4
Contact the professional who takes care of
maintenance of the appliance
Presence of the flame but insufficient ionization
(<3 µA)
4
Check that the oil valve is actually open
4
Contact the professional who takes care of
maintenance of the appliance
L05
DEF.INTERNAL
SU
Internal SU fault
The safety control box on the burner is defective
4
Contact the professional who takes care of
maintenance of the appliance
L06
DEF.SPEED.MOT
SU
Fault on the burner motor
The safety control box on the burner is defective
4
Contact the professional who takes care of
maintenance of the appliance
The burner motor is defective
4
Contact the professional who takes care of
maintenance of the appliance
L07
DEF.T.WARM UP
SU
Preheating period exceeded
The reheat fuel oil is defective
4
Contact the professional who takes care of
maintenance of the appliance
The safety control box on the burner is defective
4
Contact the professional who takes care of
maintenance of the appliance
L08
PARASIT FLAME
SU
Detection of a parasite flame
Signal present whilst there is no flame
4
Contact the professional who takes care of
maintenance of the appliance
L09
OIL.PRES FAIL.
SU
Oil pressure over limit
4
Contact the professional who takes care of
maintenance of the appliance