5 Checking and maintenance

5.1

General instructions

The boiler does not require a lot of maintenance. Nevertheless, we

recommend having the boiler inspected and serviced at regular

intervals.

4

Maintenance and cleaning of the boiler must be carried out at least

once a year by a qualified technician.

4

Have the flues swept at least once a year or more, depending on

the regulations in force in your country.

CAUTION

4

Maintenance operations must be done by a qualified

engineer.

4

We recommend taking out a maintenance contract.

4

Only original spare parts must be used.

4

Make certain that the flues and chimneys are

connected, in good condition and not blocked.

4

Do not modify nor block the condensate outlet(s).

4

If a neutralisation system is installed, follow the

instructions delivered with the neutralisation system

for cleaning and servicing of this system.

The boiler displays a message whenever maintenance is necessary.
1. When the message, REVISION, is displayed, press ? to display

the installer’s telephone number (only if the installer has input this

parameter).

2. Contact the fitter.
3. Have the required checks and services done.

5.2

Periodic checks

4

Check the water pressure in the installation (MEASURE mode).

If the water pressure is lower than 0,8 bar, more water

should be added. If necessary, top up the water level in the

heating system (recommended hydraulic pressure

between 1,5 and 2,0 bar).