Selecting the operating mode – DE DIETRICH MIT iSystem User Manual
Page 18
![background image](/manuals/329072/18/background.png)
Menu C
Parameter
Adjustment range Description
Factory setting
TEMP.TANK AUX
(2)
10 to 80 °C
Desired domestic hot water temperature in the auxiliary
circuit
55 °C
DHW A TEMP.
(2)
10 to 80 °C
Desired domestic hot water temperature in circuit A
55 °C
WATER T.NIGHT
(2)
10 to 80 °C
Desired temperature of the domestic hot water in night mode 55 °C
AUX.TANK T.NIGHT
(2)
10 to 80 °C
Desired temperature of the domestic hot water in night mode 55 °C
A.TANK T.NIGHT
(2)
10 to 80 °C
Desired temperature of the domestic hot water in night mode 55 °C
TEMP.SOL.TANK
(2)
10 to 80 °C
Temperature of the hot water produced by solar power (TS) 55 °C
SWIMMING P.T.B
(2)
5 to 39 °C
Desired temperature for swimming pool B
20 °C
SWIMMING P.T.C
(2)
5 to 39 °C
Desired temperature for swimming pool C
20 °C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
4.3.2.
Selecting the operating mode
To select an operating mode, proceed as follows:
1. Press the MODE key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key h.
Menu MODE
Parameter
Adjustment range Description
Factory setting
AUTOMATIQUE
The comfort ranges are determined by the timer programme.
DAY
7/7, xx:xx
Comfort mode is forced until the time indicated or all the time (7/7). Present time + 1
hour
NIGHT
7/7, xx:xx
Reduced mode is forced until the time indicated or all the time
(7/7).
Present time + 1
hour
HOLIDAYS
7/7, 1 to 365
The antifreeze mode is active on all boiler circuits.
Number of days' holiday: xx
(1)
heating OFF: xx:xx
(1)
Restarting: xx:xx
(1)
Present date + 1
day
SUMMER
The heating is off.
Domestic hot water continues to be produced.
COLD
Cooling mode is forced.
MANUEL
The generator operates according to the set point setting. All of
the pumps operate. Option of setting the set point by simply
turning the rotary button.
FORCE AUTO
(2)
YES
/ NO
An operating mode override is activated on the remote control
(option).
To force all circuits to run on AUTOMATIQUE mode, select
YES
.
(1) The start and end days and the number of days are calculated in relation to each other.
(2) The parameter is only displayed if a room sensor is connected.
MODE
C002267-A
4. Operating the appliance
MIT iSystem
17
24/05/2012 - 300028952-001-01