Reading out measured values, 2 reading out measured values – DE DIETRICH MIT iSystem User Manual

Page 16

background image

4.2

Reading out measured values

The various values measured by the appliance are displayed in the
#MEASURES

menu.

1. To access user level: Press the > key.
2. Select the menu #MEASURES.

4

Turn the rotary button to scroll through the menus or

modify a value.

4

Press the rotary button to access the selected menu

or confirm a value modification.

¼ For a detailed explanation of menu browsing, refer

to the chapter: "Browsing in the menus", page 12.

User level - Menu #MEASURES
Parameter

Description

Unit ROE-II ROE-H ROE+ ROE+TH ROI+

OUTSIDE TEMP.

Outside temperature

°C

x

x

x

x

x

ROOMTEMP. A

(1)

Room temperature of circuit A

°C

x

x

x

x

x

ROOMTEMP. B

(1)

Room temperature of circuit B

°C

x

x

x

x

x

ROOMTEMP. C

(1)

Room temperature of circuit C

°C

x

x

x

x

x

TEMP.MIT

Inside module flow sensor measurement

°C

x

x

x

x

x

PRESSURE

Water pressure in the installation

bar

x

x

x

x

x

WATER TEMP.

(1)

Water temperature in the DHW tank

°C

x

x

x

x

x

STOR.TANK.TEMP

(1)

Water temperature in the storage tank

°C

x

x

x

x

x

SWIMMING P.T.B

(1)

Water temperature of the swimming pool on circuit B °C

x

x

x

x

x

SWIMMING P.T.C

(1)

Water temperature of the swimming pool on circuit C °C

x

x

x

x

x

OUTLET TEMP. B

(1)

Temperature of the flow water in circuit B

°C

x

x

x

x

x

OUTLET TEMP. C

(1)

Temperature of the flow water in circuit C

°C

x

x

x

x

x

SYSTEM TEMP.

(1)

Temperature of the system flow water if multi-

generator

°C

x

x

x

x

x

T.DHW BOTTOM

(1)

Water temperature in the bottom of the DHW tank

°C

x

x

x

x

x

TEMP.TANK AUX

(1)

Water temperature in the second DHW tank

connected to the AUX circuit

°C

x

x

x

x

x

DHW A TEMP.

(1)

Water temperature in the second DHW tank

connected to circuit A

°C

x

x

x

x

x

TEMP.SOL.TANK

(1)

Temperature of the hot water produced by solar power

(TS)

°C

x

x

x

x

x

SOLAR.COLL.T.

(1)

Solar panel temperature (TC)

°C

x

x

x

x

x

SOLA.ENERGY

(1)

Solar energy accumulated in the tank

kWh x

x

x

x

x

HP OUTSIDE T.

Outside temperature measured by the heat pump

°C

x

x

x

x

x

TEMP.DEPART HP

Heat pump flow temperature

°C

x

x

x

x

x

HP RETURN TEMP

Return temperature

°C

x

x

x

COLD TEMP.

Temperature of the heat pump cold circuit

°C

x

SOURCE TEMP.

Refrigerant temperature at the heat pump source end °C

EVAPORATOR T.

Refrigerant temperature at the fin tube exchanger

outlet

°C

x

x

FLUID EVAP.T.

Fin tube exchanger refrigerant temperature

°C

x

x

FLUID COND.T.

Refrigerant temperature at the heat exchanger

°C

x

x

(1) The parameter is only displayed for the options, circuits or sensors actually connected.

bar

1

1

2

2

D

STD

J

I

E

0

2

4

6

8

10

12

14

16

18

22

24

20

#

F

AUTO

% $

<

:

!

SUNDAY 11:45

C002219-D-04

4. Operating the appliance

MIT iSystem

15

24/05/2012 - 300028952-001-01