Changing the settings, Setting the set point temperatures, 3 changing the settings – DE DIETRICH MIT iSystem User Manual
Page 17

User level - Menu #MEASURES
Parameter
Description
Unit ROE-II ROE-H ROE+ ROE+TH ROI+
HOT GAS TEMP.
Refrigerant temperature at the compressor outlet
°C
x
HOT GAS TEMP.
Compressor outlet temperature
°C
x
NB IMPULS.COMP
Number of heat pump start-ups
x
x
x
x
NB IMPULS.COMP.1
Number of start-ups on compressor 1
x
RUNTIME HP
Number of hours' operation of the heat pump
compressor
h
x
x
x
x
x
NB IMPULS.COMP.2
Number of start-ups on compressor 2
x
RUNTIME.COMP.2
Number of hours' operation of compressor 2
h
x
IN 0-10V
(1)
Voltage at input 0-10 V
V
x
x
x
x
x
SEQUENCE
Control system sequence
x
x
x
x
x
CTRL
Software control number (SCU)
x
x
x
x
x
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
4.3
Changing the settings
4.3.1.
Setting the set point temperatures
To set the various heating, DHW and swimming pool temperatures,
proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key h.
Menu C
Parameter
Adjustment range Description
Factory setting
DAY TEMP. A
5 to 30 °C
Desired room temperature in comfort periods on circuit A
20 °C
NIGHT TEMP. A
5 to 30 °C
Desired room temperature in reduced periods on circuit A
16 °C
ROOMTEM.COOL A
(1)
(2)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
DAY TEMP. B
(2)
5 to 30 °C
Desired room temperature in comfort periods on circuit B
20 °C
NIGHT TEMP. B
(2)
5 to 30 °C
Desired room temperature in reduced periods on circuit B
16 °C
ROOMTEM.COOL B
(2)
(1)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
DAY TEMP. C
(2)
5 to 30 °C
Desired room temperature in comfort periods on circuit C
20 °C
NIGHT TEMP. C
(2)
5 to 30 °C
Desired room temperature in reduced periods on circuit C
16 °C
ROOMTEM.COOL C
(2)
(1)
22 to 30 °C
Desired room temperature set point in cooling mode
25 °C
WATER TEMP.
(2)
10 to 65 °C
Desired domestic hot water temperature in the DHW circuit 55 °C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
MODE
C002266-A
MIT iSystem
4. Operating the appliance
24/05/2012 - 300028952-001-01
16