Adjustment parameter mm - operating mode – DE DIETRICH DIETRISOL TRIO DT 250 - TRIO DT 350 User Manual
Page 16

16
TRIO DT 250 - TRIO DT 350
17/10/12 - 300028005-001-03
In order for the regulator to calculate the quantity of heat produced by
the installation (parameter kWh), input parameter Fx. The parameter
Fx is equal to the flow in litres per minute in the solar circuit.
Determine the value Fx using the following tables, according to the
configuration of the installation and the number or surface area of the
collectors. When the flow is input incorrectly, the display kWh will also
be incorrect.
The quantity of heat (kWh value) can only be used for checks
carried out for personal reasons.
`
Flat solar panels
`
Tubular solar panels
Adjustment parameter MM - Operating mode
Adjustment range: 0 ... 4
Factory setting: 4
For inspection and maintenance work, it is possible to operate the
regulator in manual mode. To operate the regulator in manual mode,
it is necessary to input parameter MM from the following table.
Solar panel
installation
Area
m
2
Number of
panels
Flow rate
l/h
Flow rate
l/min
3 ... 5
1 or 2
400
6.7
6 ... 8
3 or 4
300
5
8 ... 10
4 or 5
250
4.1
8 ... 10
2x2
750
12.5
12 ... 15
2x3
670
11.2
16 ... 20
2x4
450
7.5
12 ... 15
3x2
850
14.2
18 ... 23
3x3
800
13.4
24 ... 30
3x4
650
10.9
16 ... 20
4x2
1200
20
24 ... 30
4x3
850
14.2
Number of panels
Flow rate
l/h
Flow rate
l/min
minimum: 1x4
820
13.7
1x5
750
12.5
1x6
680
11.4
1x7
610
10.2
1x8
540
9
1x9
470
7.8
1x10
250
4.1
2x3
1400
20
2x4
1250
20
2x5
1100
18.4
2x6
950
15.9
2x7
750
12.5
2x8
600
10
2x9
540
9
2x10
400
6.7
MM1
R1
R2
LED
0
Open
Open
Flashing green/red
1
Closed
Open
Flashing green/red
2
Open
Closed
Flashing green/red
3
Closed
Closed
Flashing green/red
4
automatic
automatic
automatic