beautypg.com

DE DIETRICH INNOVENS MCA 35 User Manual

Page 33

background image

Code Messages

Description

Checking / solution

B08

BL.RL OPEN

The RL inlet on the PCU PCB

terminal block is open

Parameter error

4

Contact the professional who takes care of maintenance of

the appliance

Bad connection

4

Contact the professional who takes care of maintenance of

the appliance

B09

BL.INV. L/N

4

Contact the professional who takes care of maintenance of the appliance

B10
B11

BL.BL INPUT
OPEN

The BL inlet on the PCU PCB

terminal block is open

The contact connected to the BL inlet is open

4

Contact the professional who takes care of maintenance of

the appliance

Parameter error

4

Contact the professional who takes care of maintenance of

the appliance

Bad connection

4

Contact the professional who takes care of maintenance of

the appliance

B13

BL. PCU COM

Communication error with the

SCU PCB

Bad connection

4

Contact the professional who takes care of maintenance of

the appliance

SCU PCB not installed in the boiler

4

Contact the professional who takes care of maintenance of

the appliance

B14

BL.WATER MIS.

The water pressure is lower than

0,8 bar

Not enough water in the circuit

4

Top up the installation with water

B15

BL.GAS PRESS

Gas pressure too low

Incorrect setting of the gas pressure switch on the SCU PCB

4

Check that the gas valve is fully opened

4

Contact the professional who takes care of maintenance of

the appliance

B16

BL.BAD SU

The SU PCB is not recognised

Wrong SU PCB for this boiler

4

Contact the professional who takes care of maintenance of

the appliance

B17

BL.PCU ERROR

The parameters saved on the

PCU PCB are impaired

Parameter error on the PCU PCB

4

Contact the professional who takes care of maintenance of

the appliance

B18

BL.BAD PSU

The PSU PCB is not recognised Wrong PSU PCB for this boiler

4

Contact the professional who takes care of maintenance of

the appliance

B19

BL.NO CONFIG

The boiler has not been

configured

The PSU PCB has been changed

4

Contact the professional who takes care of maintenance of

the appliance

B21

BL. COM SU

Communication error between

the PCU and SU PCBs

Bad connection

4

Contact the professional who takes care of maintenance of

the appliance

B22

BL.FLAME LOS

No flame during operation

No ionization current

4

Check that the gas valve is fully opened

4

Contact the professional who takes care of maintenance of

the appliance

B25

BL.SU ERROR

Internal error on the SU PCB

4

Contact the professional who takes care of maintenance of

the appliance

MCA 35

6. Troubleshooting

24/08/2011 - 300024162-001-B

32