DE DIETRICH INNOVENS MCA 35 User Manual

Page 18

background image

User level - #MEASURES menu

Parameter

Description

Unit

OUTSIDE TEMP.

Outside temperature

°C

ROOMTEMP. A

(1)

Room temperature of circuit A

°C

ROOMTEMP. B

(1)

Room temperature of circuit B

°C

ROOMTEMP. C

(1)

Room temperature of circuit C

°C

BOILER TEMP.

Water temperature in the boiler

°C

PRESSURE

Water pressure in the installation

bar

WATER TEMP.

(1)

Water temperature in the DHW tank

°C

INST DWH TEMP.

(1)

Instant hot water temperature

°C

STOR.TANK.TEMP

(1)

Water temperature in the storage tank

°C

DCW TEMPERATURE

Domestic cold water temperature

°C

SWIMMING P.T.B

(1)

Water temperature of the swimming pool on circuit B

°C

SWIMMING P.T.C

(1)

Water temperature of the swimming pool on circuit C

°C

OUTLET TEMP. B

(1)

Temperature of the flow water in circuit B

°C

OUTLET TEMP. C

(1)

Temperature of the flow water in circuit C

°C

SYSTEM TEMP.

(1)

Temperature of the system flow water if multi-generator

°C

T.DHW BOTTOM

(1)

Water temperature in the bottom of the DHW tank

°C

TEMP.TANK AUX

(1)

Water temperature in the second DHW tank connected to the AUX circuit °C

DHW A TEMP.

(1)

Water temperature in the second DHW tank connected to circuit A

°C

BACK TEMP

Temperature of the boiler return water

°C

WIND SPEED

Fan rotation speed

rpm

POWER

Instantaneous boiler output (0%: Burner off or running at minimum output) %

CURRENT

(µA)

Ionization current

µA

NB IMPULS.

Number of burner start-ups (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME

Number of burner operation hours (not restartable)

The meter is incremented by 2 every 2 hours

h

IN 0-10V

(1)

Voltage at input 0-10 V

V

SEQUENCE

Control system sequence

CTRL

Software control number

(1) The parameter is only displayed for the options, circuits or sensors actually connected.

4. Operating the boiler

MCA 35

17

24/08/2011 - 300024162-001-B