8 Technical specifications
8.1
Technical specifications
Boiler type
MCA 45
MCA 65
MCA 90
MCA 115
General
Flow rate setting
Adjustable
Modulating, Start/Stop, 0 - 10 V
Nominal output (Pn)
Heating System (80/60 °C)
minimum-maximum kW
8,0 - 40,0 12,0 - 61,0 14,1 - 84,2 16,6 - 107,0
Factory setting
kW
40,0
61,0
84,2
107,0
Nominal output (Pn)
Heating System (50/30 °C)
minimum-maximum kW
8,9 - 43,0 13,3 - 65,0 15,8 - 89,5 18,4 - 114,0
Factory setting
kW
43,0
65,0
89,5
114,0
Data on the gases and combustion gases
Gas consumption G20 (Natural gas H) minimum-maximum m
3
/h
0,9 - 4,4
1,3 - 6,6
1,5 - 9,1
1,8 - 11,7
Gas consumption G31 (Propane)
minimum-maximum m
3
/h
0,3 - 1,7
0,5 - 2,5
0,6 - 3,5
0,6 - 4,7
NOx-Emission per year (EN 483)
mg/kWh 37
32
45
46
Mass flue gas flow rate
minimum-maximum Kg/h
14 - 69
21 - 104
28 - 138
36 - 178
Flue gas temperature
minimum-maximum °C
30 - 67
30 - 68
30 - 68
30 - 72
Maximum counter pressure
Pa
150
100
160
220
Characteristics of the heating circuit
Water content
l
5,5
6,5
7,5
7,5
Water operating pressure
minimum
kPa (bar) 80 (0,8)
80 (0,8)
80 (0,8)
80 (0,8)
Water operating pressure (PMS)
maximum
kPa (bar) 400 (4,0) 400 (4,0)
400 (4,0)
400 (4,0)
Water temperature
maximum
°C
110
110
110
110
Operating temperature
maximum
°C
90
90
90
90
Electrical characteristics
Power supply voltage
V/Hz
230/50
230/50
230/50
230/50
Power consumption - Full load
maximum
W
68
88
125
199
Power consumption - Part load
maximum
W
18
23
20
45
Power consumption - Standby
maximum
W
5
6
4
7
Electrical protection index
IP
X4D
X4D
X4D
X4D
Other characteristics
Weight (empty)
Total
kg
53
60
67
68
Acoustic level at 1 metre
dBA
45
45
52
51
8. Technical specifications
MCA 45 - 65 - 90 - 115
51
28/08/12 - 300024828-001-01