Domestic hot water tanks – DE DIETRICH ALEZIO AWHP-V220 User Manual
Page 30
AWHP-V220
4 MR
6 MR
8 MR
11 MR 11 TR
14 MR 14 TR
16 MR 16 TR
Max pre-loaded length
m
30
30
30
30
30
30
30
30
30
Weight (empty) - Outside module kg
45
45
75
121
135
116
130
116
130
Weight (empty) - Indoor module
kg
35
35
35
37
37
37
37
37
37
(1) Hot mode: Outside air temperature +7 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(2) Hot mode: Outside air temperature +2 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(3) Only in reversible versions
(4) Cooling mode: Outside air temperature +35 °C, Water temperature at the outlet +18 °C. Performances in line with EN 14511-2
(5) 5 m from the appliance, free field.
(6) Noise spread by the envelope - Test conducted in accordance with the standard NF EN 12102
7.1.2.
Domestic hot water tanks
Technical specifications
Primary circuit
(Heating water)
Maximum operating temperature °C
85
Maximum operating pressure
bar
3
Exchanger capacity
L
14
Exchange surface
m
2
1.7
Secondary circuit
(domestic water) Maximum operating temperature °C
70
Maximum operating pressure
bar 10
Water content
L
220
Weight
Shipping weight
kg 112
Domestic hot water tank loading time
AWHP-V220
4 MR
6 MR
8 MR
11 MR - 11 TR 14 MR - 14 TR 16 MR - 16 TR
Heating time
(1)
2 h 39 min 1 h 42 min 1 h 25 min 1 h 19 min
1 h 16 min
1 h 14 min
(1) ΔT = 40 K. Outside air temperature: 7 °C. Inside air temperature: 20 °C
7. Technical specifications
AWHP-V220
29
23/04/2013 - 300026802-001-03