beautypg.com

Domestic hot water tanks – DE DIETRICH ALEZIO AWHP-V220 User Manual

Page 30

background image

AWHP-V220

4 MR

6 MR

8 MR

11 MR 11 TR

14 MR 14 TR

16 MR 16 TR

Max pre-loaded length

m

30

30

30

30

30

30

30

30

30

Weight (empty) - Outside module kg

45

45

75

121

135

116

130

116

130

Weight (empty) - Indoor module

kg

35

35

35

37

37

37

37

37

37

(1) Hot mode: Outside air temperature +7 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.

(2) Hot mode: Outside air temperature +2 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.

(3) Only in reversible versions

(4) Cooling mode: Outside air temperature +35 °C, Water temperature at the outlet +18 °C. Performances in line with EN 14511-2

(5) 5 m from the appliance, free field.

(6) Noise spread by the envelope - Test conducted in accordance with the standard NF EN 12102

7.1.2.

Domestic hot water tanks

Technical specifications

Primary circuit

(Heating water)

Maximum operating temperature °C

85

Maximum operating pressure

bar

3

Exchanger capacity

L

14

Exchange surface

m

2

1.7

Secondary circuit

(domestic water) Maximum operating temperature °C

70

Maximum operating pressure

bar 10

Water content

L

220

Weight

Shipping weight

kg 112

Domestic hot water tank loading time
AWHP-V220

4 MR

6 MR

8 MR

11 MR - 11 TR 14 MR - 14 TR 16 MR - 16 TR

Heating time

(1)

2 h 39 min 1 h 42 min 1 h 25 min 1 h 19 min

1 h 16 min

1 h 14 min

(1) ΔT = 40 K. Outside air temperature: 7 °C. Inside air temperature: 20 °C

7. Technical specifications

AWHP-V220

29

23/04/2013 - 300026802-001-03