Energy consumption display, Ab c d – DE DIETRICH ALEZIO AWHP-V220 User Manual
Page 21
![background image](/manuals/329035/21/background.png)
2. Use the B (-) and C (+) keys to scroll through the information.
If no buttons are pressed for 10 seconds, the screen goes
back to the main display.
For permanent information display:
When the word SERVICE flashes, press the A (G) and B
(-)
keys simultaneously.
The word SERVICE continues to be displayed and no
longer flashes.
3. Press the key A (G) to exit the menu.
If the information SERVICE is not displayed, the screen will
switch back to the main display after 5 seconds.
The following data can be accessed in the information menu:
Parameter Description
Unit
pB
4
In heating mode: Heating flow set point temperature
4
In DHW mode: DHW setpoint temperature
4
In cooling mode: Cooling setpoint temperature
4
In swimming pool mode: Pool set temperature
°C
pC
Measured start temperature
°C
pD
Domestic hot water temperature measured
°C
pE
Outside temperature measured
°C
lp
Water flow
l/min
F.jp
Software version
4.4.1.
Energy consumption display
Parameter Description
Unit
gB:
Estimated consumption of electrical energy in heating mode
(1)
kWh
gC:
Estimated consumption of electrical energy in DHW mode
(1)
kWh
gD:
Estimated consumption of electrical energy in cooling mode
(1)
(2)
kWh
(1) Display available if the estimated electrical energy consumption function is activated
(2) Cooling mode must be enabled
The estimated electricity consumption is displayed in 3 digits. The
fourth digit indicates the scale (x1, x10, x100, x1000).