BEI Sensors High Resolution Inclinometers User Manual
Page 2
Page 2
Inclinometer RS232
– Current Datasheet
Version: 20130503
INCLI NO MET E R
RS2 32
– CURRENT
1 Technical Data
1.1 Electrical Data
Model
INC 5
INC 15
INC 30
Measuring range
+/- 5°
+/- 15°
+/- 30°
Resolution digital
0.001°
0.001°
0.01°
Resolution analog
0,001°
0,005°
0,01°
Accuracy Digital
1)
+/-0,01°
+/-0,01°
+/-0,02°
Accuracy Analog
1)
+/-0,05°
+/-0,05°
+/-0,05°
Temperture Gradient
2)
+0.001°/K
+0.002°/K
+0.003°/K
Inclination angle in x and y
1)
+/-15°
+/-40°
+/-60°
Damping period 5° > 0°
Typical 1 s 10 %, 2 s 1 %, 3 s 0.1 %
Digital interface
RS232 format ASCII
Baud rate
Max. 56 k
Analog interface
4 to 20mA, 0°= 12mA, Load 300 Ohm
Supply voltage
10 to 30 V DC (absolute limits)
Current consumption
Typical 50 mA
EMC
Emitted interference: EN 61000-6-3
Noise immunity: EN 61000-6-2
Electrical lifetime
> 10
5
h
1) T = +25°C, 90% total measurement range
2) e.g. temperature drift AGS005 (T= 0°C up to +55°C) = 55K * 0,001°/K = 0,055°
3) Supply voltage is applied.
4) Inclinometers should be connected only to subsequent electronics whose power supplies comply with EN 50178 (protective low
voltage)