CANopen Industrial Datasheet
Version 130305
INCLI NO MET E R
CA NOPE N
Technical Data
Electrical Data
Model
INC 5
INC 15
INC 30
Measuring range
+/- 5°
+/- 15°
+/- 30°
Resolution
0.001°
0,001°
0,005°
Accuracy (T = 0 °C .. +55 °C)
0,01°
0,01°
0,02°
Inclination angle in x and y (1)
+/-15°
+/-40°
+/-60°
Damping period 0° -> 5°
typical 1s 10%, 2s 1%, 3s 0,1%
Interface
Transceiver according ISO 11898,
galvanically isolated by opto-couplers
Transmission rate
max. 1 MBaud
Device addressing
Adjustable by rotary switches in connection cap
Supply voltage (2)
10
– 30 V DC (absolute limits)
Current consumption
max. 230 mA with 10 V DC, max. 100 mA with 24 V DC
Power consumption
max. 2.2 Watts
EMC
Emitted interference: EN 61000-6-4
Noise immunity:
EN 61000-6-3
Electrical lifetime
> 10
5
h
(1) Supply voltage is applied.
(2) Inclinometers should be connected only to subsequent electronics whose power supplies comply with
EN 50178 (protective low voltage)
Mechanical Data
Housing
Aluminum
Lifetime
> 10
5
h
Shock
A=30g; t= 11ms, halfsine (EN 60068-2-27)
Vibration
10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration,
1 Octave /Minute (EN 60068-2-6)
Weight (standard version)
350 g
Environmental Conditions
Operating temperature
-40°C......+85°C
Storage temperature
-40°C......+85°C
Humidity
98 % (without liquid state)
Protection class
IP 67 (connected) (EN 60529)