BEI Sensors Industrial Duty Inclinometers User Manual
Page 3

Page 3
Analog Industrial Data Sheet
Version: 20130503
INDUST RIAL I NCLI NOME T ER
ANA LOG & RS 232 I NT ER F ACE
Environmental Conditions
Operating Temperature
-40 °C to +85 °C / -40 °F to 185 °F
Humidity
98 % Relative Humidity, Non-Condensing
Protection Class (EN 60529)
IP 69K (With Appropriate Counter Connector), IP68, IP67
MTBF Data
Failure Rate [FIT]
759
MTBF [Hours]
1,317,822
MTBF [Years]
150
The data mentioned above were calculated for inclinometer electronics under the following conditions:
− SNA: Non-mobile operation
− Tu: 40°C - Mean component of ambient temperature
− Zf: Continuous operation for 8760 h per year
Default Factory Settings
Operational Mode
Continuous Mode
Resolution
0.01°
Output Transmission Rate
100 ms
Baud Rate
9600 Baud
Moving Average Filter
64
Angle Offset
0