1.R em ove the draw er of the outdoor unit.
2.N on-quick coupler:connect the indoor pow er and control
w ires w ith the m atched outdoor w ires in accordance
w ith the electric schem atic diagram and m ake sure
that the connection is firm ly done
Q uick coupler:directly connect quick cable couplers w ith
indoor and outdoor quick cable couplers after disassem bly
of the outdoor unit connecting box cover
w ire pressing plate
D raw er
screw
3.U se a press plate to fix the w ires firm ly,and re-install
the draw er.
N ote:D o not connect the w ires in a w rong w ay,otherw ise electric m alfunctions w ill be caused and
even dam ages to the units w ill occur.The appliance shall be installed in accordance w ith national
w iring regulation.If the supply cord is dam aged,it m ust be replaced by the m anufacturer or its service
agent or a sim ilarly qualified person in order to avoid a hazard.The plug shall be accessible after
installing the appliance.If the m odel have not plug that a sw itch w hich have a contact separation
of at least 3 m m (1/10") in all poles shalled be added in fixed w iring.
* U se therm al tube to w rap the joints and w rap the tube tightly w ith ethylene tapes.
* Fix the w rapped pipelines on the exterior w all w ith clam ps.
* Fill in the gaps left over by the pipeline hole and w all hole to prevent rain-w ater from entering.
*
Finishing touches
*
* C onnect to the pow er source,check if the function selection keys on the rem ote controller are
w orking properly.
* C heck if the room tem perature adjustm ents and tim er settings are w orking properly.
* C heck if the drain is sm ooth.
* C heck if there is any abnorm al noise or vibration during operation.
* C heck if there is leakage of refrigerant.
*
Test running
*
Fig.9
Fig.10
(Fig.9).
(Fig.10).
*
Is the unit installed correctly?
*
*Isn'
t there anything w hich prevents ventilation or obstructs operation in front of the indoor unit ?
D o not install the unit follow ing place .
*Inflam m able gases m ay leak .
*O il splashes a lot .
*In case w here the uni
t i
s used i
n such pl
aces as poi
sonous or sul
try gases are generated or seasi
de
district exposed to sea breezes corrosion m ay cause m alfunction . C onsult w ith your distributor .
*Ai
r condi
ti
oner body and rem ote control
l
er m ust be I m (39-3/4") or m ore aw ay from a TV or a radi
o.
D rain the dehum idified w ater from the indoor unit to a place w hich drains w ell .
*W hen installing the unit , choose a place w hich can stand the w eight of the unit w ell and does
not increase the operation noise or vibration . Especially w here there is a possibility that vibration
be transm itted to the house , fix the unit by inserting attached vibration -proof pads betw een the
unit and fittings .
*Suitable Installation Position
*Pay attention to operation noise