H eight lim its of indoor and outdoor units – Amcor UCHW-H09AF2 User Manual
Page 14

1
*S election of installation positions for indoor unit*
* To be installed at the position w here the air delivered from the unit can reach every corner of
the room ;
* To avoid being affected by the outdoor air;
* To avoid blockage to the air inlet or outlet of the unit;
* To avoid too m uch oil sm oke or steam ;
* To avoid possible generation, inflow , lingering or leakage of flam m able gases;
* To avoid high-frequency facilities (such as high frequency arc w elders, etc.);
* To avoid the places w here acid solutions are frequently used;
* To avoid the places w here som e special sprayers (sulfides) are frequently used.
* N ot to install a fire alarm ing device near the air outlet of the unit (during operation, the fire alarm
device m ight be erroneously triggered by the w arm air from the unit);
IN STALLATIO N & R EPAIR G U ID E
Split W all-M ounted Air C onditioner
Above 100m m (4")
Left side: 150m m (6")
and above
R ight side: 150m m (6")
and above
C eiling
W all hanging plate
ground
2300m m (7'
6")
and above
* M ake sure of enough space for installation and m aintenance.
* To take into consideration the operational convenience and safety in installation, it is recom m ended
to ensure enough space betw een the unit and the w alls.
* H eight lim its of indoor and outdoor units.
* Either the indoor unit or the outdoor unit can be higher, but the height difference m ust com ply the stated
requirem ents.
* Try to reduce the bending of the piping line as m uch as possible so as to avoid possible negative im pacts upon the
perform ances of the units.
Indoor unit
outdoor
unit
5m (16'
5")m ax.