Rl series feature string nomenclature, Feature 12: controls, Feature 13: special controls – AAON RL-240 User Manual
Page 19: Feature 14: preheat, Feature 15: option boxes, Feature 16: interior cabinet options, Feature 17: cabinet options
19
RL Series Feature String Nomenclature
:
S
IZE
V
LT
C
O
N
F
IG
A1
A2
A3
A4
B1
B2
B3
1A
1B
1C
1D
2
3
4
5A
5B
5C
6A
6B
6C
7
8
9
10
11
12
13
14A
14B
15
16
17
18
19
20
21
22
23
R L
–
1 0 0
–
3
–
0
–
B E 0 6
–
3 5 2 : B E B E
–
D 0 0
–
Q F Y
–
P 0 A
–
0 D B B 0 0 0
–
0 0
–
0 B B 0 0 AB 0 B
G
EN
Model Options
Unit Feature Options
Feature 12: CONTROLS
0 = Standard, Terminal Block
A = Low Limit Controls
B = Phase and Brown Out Protection
C = ERW Defrost
D = ERW Rotation Detection
F = Option A + B
G = Option A + C
H = Option A + D
K = Option B + C
L = Option B + D
N = Option C + D
Q = Option A + B + C
R = Option A + B + D
T = Option A + C + D
V = Option B + C + D
Y = Option A + B + C + D
Feature 13: SPECIAL CONTROLS
0 = Standard
D = VAV Unit Controller
E = Constant Volume Unit Controller
F = MakeUp Air Unit Controller
H = Field Installed DDC Control by Others
J = Factory Installed DDC Controls by Others
5 = Field Installed DDC Controls w/ iso relays
6 = Factory Installed DDC Controls by other w/
relays
Feature 14: PREHEAT
14A: PREHEAT CONFIGURATION
0 = No Preheat
C = Hot Water Coil, OA Preheat
D = Steam Distributing Coil, OA Preheat
E = Hot Water Coil, Preheat 4ft Box
F = Steam Distributing Coil, Preheat 4ft Box
14B: PREHEAT SIZING
0 = No Preheat
A = Heat Qty A
B = Heat Qty B
C = Heat Qty C
D = Heat Qty D
Feature 15: OPTION BOXES
0 = Standard
A = 2 ft Box After Heat
B = 2 ft Box After Cooling
C = 2 ft Box After Pre Filter
D = 2 ft Box After Return
E = 4 ft Box After Heat
F = 4 ft Box After Cooling
G = 4 ft Box After Pre Filter
H = 4 ft Box After Return
J = 6 ft Box After Heat
K = 6 ft Box After Cooling
L = 6 ft Box After Pre Filter
M = 6 ft Box After Return
N = 8 ft Box After Heat
P = 8 ft Box After Cooling
Q = 8 ft Box After Pre Filter
R = 8 ft Box After Return
S = 2 ft Box After Preheat Coil
T = 4 ft Box After Preheat Coil
U = 6 ft Box After Preheat Coil
V = 8 ft Box After Preheat Coil
Feature 16: INTERIOR CABINET
OPTIONS
0 = Standard
B = Marine Service Lights
Feature 17: CABINET OPTIONS
0 = Standard
A = Access Door Windows
B = Burglar Bars
C = Perf Liner, SA Plenum
D = Perf Liner, RA Plenum
F = Option A + B
G = Option A + C
H = Option A + D
K = Option B + C
L = Option B + D
N = Option C + D
Q = Option A + B + C
R = Option A + B + D
T = Option A + C + D
V = Option B + C + D
Y = Option A + B + C + D