beautypg.com

Allied Telesis AR700 User Manual

Page 7

background image

Features in 281-01

7

Version 281-01
C613-10482-00 REV A

CR00011434

File

2

The router or switch sometimes rebooted when copying a very large file (several
Mbytes). This issue has been resolved by improving the copy process so that it
uses fewer memory buffers.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00011670

Switch

2

On x900-48 Series switches, when the switch used a DSCP map to remark
packets, it did not mark the packets correctly.

This issue has been resolved.

-

-

-

-

-

-

-

Y

-

-

CR00012364

IPv6

2

For IPv6, if there were multiple equal cost multipath (ECMP) static routes to a
destination, and one or more links for the routes became inactive, the inactive
route was sometimes still chosen for forwarding. This caused brief data delivery
failure to the destination.

This issue has been resolved.

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00012534

IP Gateway

2

If the router or switch received an IP packet that had been sent as an Ethernet
broadcast, the router or switch responded as if the packet had been sent to its IP
address, even when the packet was destined for a different IP address. In
particular, the router or switch processed and responded to ICMP and TCP
packets that were sent as Ethernet broadcasts to different IP addresses. These
caused the router or switch to send ICMP echo responses or TCP reset packets.

This issue has been resolved. Such Ethernet broadcast packets are generally not
valid packets, so the router or switch now discards them.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR

Module

Level

Description

AR4

0

0

AR7

x

5

AR7

50S / AR770S

Ra

pi

er

i

AT

-8

8

0

0

AT

-8

6

0

0

A

T-

8

7

00XL

A

T-

8

9

48 / x900-

48

AT

-9

9

0

0

AT

-9

8

0

0

This manual is related to the following products: