beautypg.com

Level 4 – Allied Telesis AR700 User Manual

Page 18

background image

Features in 281-01

18

Version 281-01
C613-10482-00 REV A

Level 4

CR

Module

Level

Description

AR400

AR7x5

AR750S

/

AR77

0S

Rapi

er

i

A

T-

8800

A

T-

8600

A

T-

8700

XL

A

T-

8948

/

x90

0-

4

8

A

T-

9900

A

T-

9800

CR00010159

GUI

4

When the web-based GUI is used to add or remove ports from a port-based
VLAN association on an AT-9812T switch, the icons representing alternate ports
faced opposite directions.

This issue has been resolved. The port icons now all have the same orientation.

-

-

-

-

-

-

-

-

-

Y

CR00011311

IPsec

4

In output of the commands show ipsec policy and show ipsec policy
sabundle
, the value for the number of bytes currently used by each SA bundle
was sometimes truncated.

This issue has been resolved, and both commands now display the correct
number. As part of this, output of the command show ipsec policy has been
modified so that the expiry limits in bytes and in seconds display on separate
lines.

Also, if the expirykbytes parameter of the command create or set ipsec
bundlespecification
was given a value higher than 4193280, the router or
switch instead used a lower value.

This issue has been resolved. If you specify a value above 4193280, the router or
switch now displays a warning message and sets the expiry limit to 4193280
kbytes.

Y

Y

Y

Y

Y

-

-

-

-

-

CR00011788

IP Gateway

4

Previously the switch allowed users to specify the tag parameter when creating
or modifying a blackhole route with the commands add or set ip route.
However, blackhole routes cannot be tagged, so the switch did not apply the tag
setting in its saved configuration.

This issue has been resolved. If a command contains both the blackhole and tag
parameters, the switch now returns an error message.

-

-

-

-

-

-

-

Y

Y

-

This manual is related to the following products: