5 - automatic gauges – CEMB USA C72 (B) User Manual
Page 25
I 0307_0308 -
25
GB
6.5 - AUTOMATIC GAUGES
6.5.1 - RIM DISTANCE GAUGE
- Shift the distance gauge to position
, keeping it quite still,
press
- Move the gauge to position
, press
CORRECT CALIBRATION
- Return the gauge to rest position
- The wheel balancer is ready for operation
N.B.: In the event of errors or faulty operation, the writing
appears on the display : shift
the gauge to position
and repeat the calibration operation exactly as described above. If the
error persists, contact the Technical Service Department. In the event of incorrect input in the rim
distance gauge calibration function, press
to cancel it.
6.5.2 - DIAMETER GAUGE
- Currently preset diameter.
- Set the diameter with which to calibrate the machine (10÷18”)
with
- Press
- Move the gauge tip into measuring position (Fig. 8/Pos.A) and
keeping it still, press
CORRECT CALIBRATION
- Return the gauge to rest position
- The wheel balancer is ready for operation
In the event of incorrect input in the rim distance gauge calibration function, press
to cancel it.